Test stand for pumps and hydraulic motors of road-building machines
The stand is used for testing
pumps and hydraulic motors of road-building machines after routine and capital
repair. The stand
checks pumps functioning per GOST 14658-86 and hydraulic motors functioning per GOST
20719-83 to the extent as
specified by the statement of work approved by the Customer.
The stand allows checking pumps and
hydraulic motors functioning (brand marks of equipment tested and test
conditions are given in the tables below).
Pumps are tested for:
- excessive
vibration, shock, knocking, sharp noise, line pressure surge, excessive heating
- drop formation along the covers, plugs, flanges, joints, etc.
- amount of working fluid supply and its consistency at the given direction of output shaft rotation
- change of working fluid supply amount during control mechanisms operation
- response to load change (output pressure)
Hydraulic motors are tested for:
- excessive vibration, shock, knocking, sharp noise, line pressure surge, excessive heating, conditions of working fluid outlet from the drain pipe (uniformity, air bubbles, etc.)
- working fluid leaks from plugs, flanges, shaft, etc.
- rotation of hydraulic motor output element during working fluid supply to working cavities
- change of rotation of hydraulic motor output element when changing working fluid supply to the working cavities
Pumps brand marks and test conditions:
Pump
|
Ðtest,
MPa
|
|
|
Ntest,
kW
|
333.355.100.220
|
20
|
168
|
1,500
|
56
|
NSh-100À-3L
|
16
|
135
|
1,500
|
36
|
NSh-71À-3L
|
20
|
105
|
1,500
|
35
|
NSh-50 U-2
|
16
|
73
|
1,500
|
20
|
NSh-50
|
14
|
73
|
1,500
|
17
|
74860276
|
6.5…7.3
|
86
|
1,500
|
10
|
2909124SL
|
1
|
45
|
1,500
|
0.75
|
NSh-10P-3
|
16
|
13
|
1,500
|
3.5
|
Hydraulic
motors brand marks and test conditions:
Hydraulic motors
|
Ðtest,
MPa
|
Qtest, l/min
|
ntest, rev/min
|
Ntest,
kW
|
310.3.56.00
|
20
|
2.8…100
|
50…1,800
|
30
|
310.2.56.00
|
20
|
2.8…100
|
50…1,800
|
30
|
310.3.112.00
|
20
|
5.6…201
|
50…1,800
|
60
|
303.3.112.501
|
20
|
5.6…201
|
50…1,800
|
60
|
303.3.112.501.002
|
20
|
5.6…201
|
50…1,800
|
60
|
MN-250
|
16
|
12.5…250
|
50…1,000
|
60
|
Stand
performance
|
No
less than 3 standard-size hydraulic units per 8 hours
|
Total
consumed power, kW
|
60.5
|
Ambient
temperature, ºÑ
|
10…25
|
Water
temperature at the heat exchanger inlet, ºÑ
|
0…30
|
Working
fluid viscosity, cSt
|
10…30
|
Reservoir
volume, m3
|
1.2
|
Stand
dimensions (WxLxH), mm
|
2,000x4,500x2,000
|
Apart
from the hydraulic units specified above, the stand can be used to test any
hydraulic units which fit stand capacities. Cheltec is able to design and manufacture any
necessary adapters.